Ocean Jewels Takes Hurricane Matthew by STORM!
On October 7th, 2016, Hurricane Matthew cruised up the southeastern seaboard for up to 24 hours. Matthew never made landfall in Florida; however, it still hurled the Atlantic ocean with wind and flooding in it’s wake. As of Friday at 11 p.m., the storm was downgraded to Category 2 and sustained maximum winds dropped to 105 mph. Hurricane Mathew was a challenging event for many Floridians. Integrated Roofing Systems, Inc. (IRSI) has been visiting coastal buildings on the east coast of Florida in Volusia County. Ralph Jewell, Vice President of IRSI reported he has seen a lot of roof failure, structural damage and water damage, especially ocean front. IRSI has focused on discovering and recording the type of roofs that did well and the type that failed. Although there are many factors that contribute to roof performance in strong winds and rains, we have narrowed down the common shared traits of the roofs that successfully performed.
While inspecting fully adhered failed roofs, we discovered 3 common reasons for the failure. Either the bonding adhesive (glue) failed, the adhesion to the insulation failed or the insulation adhesion to the deck failed. Some failures could be attributed to poor installation workmanship, poor design, corrosion and aging, and some was due to older designs that don't meet current wind code.
We also inspected many mechanically attached roofs that failed. Failures here came from fasteners that pulled out of the deck or rotted wood nailer, fastener s that ripped through the base membrane, fasteners that were corroded and lost their structural holding capacity, and poor workmanship that did not follow current code.
All of the failed roofs had one thing in common. The failed roofs were designed to work against Mother Nature’s damaging high winds.
There is a different and much better approach. One that works with Mother Nature and uses the wind pressure to keep the roof tight to the structure during high winds. That system is the “Wind Vented Roof” design. Building owners with “Wind Vented Roof” systems up and down the coast reported zero wind- related failures. I personally inspected numerous “Wind Vented Roof” installations and found zero failures.
Ocean Jewels Condominium in Daytona Beach is a beautiful ocean front resort that recently sustained roof, structural and severe water damage during Hurricane Mathew. Since this resort has multiple types of roof systems on their buildings in the same complex, we are offered a unique window to analyze differences between roofs that performed and roofs that failed when subjected to the same damaging wind speeds.
The Ocean Jewels complex has 7 buildings. 2 of those buildings have roofs that were installed using “Wind-Vented Roof” technology. 5 of those buildings have roofs that were fully adhered and one roof that was mechanically attached.
The roofs of 2 buildings not only blew off, but took some of the structural roof decking with it. Two of the roofs that were retrofitted with the wind-vented technology survived. It was the same type of deck on all buildings, same location , same wind speeds and the wind-vented proved again that this method of installation offers the building owner superior performance in high wind events.
Failed Roofs - 4 of the 5 buildings with traditionally installed roofing either completely or mostly blew off causing leaks in almost all top floor units. Some areas just lost the roof, and some areas lost the roof and the insulation.
2 units in one building lost the structural wood deck after becoming exposed and vulnerable when the roof blew off. Unfortunately, these units suffered total catastrophic loss.
Wind-Resistant Roofs - Two of the traditional designs (that failed) had been roofed over in 2013 using the “Wind Vented Roof” technology. The “Wind Vented Roofs” experienced zero wind damage. Keep in mind the “Wind Vented Roofs” which were installed in 2013 went over the exact same type and age of deck, same building height, same traditional type of roof at the same location, and experienced no blow off. The “wind Vented Roof” did experience some punctures and holes in the membrane due to flying debris from the adjacent failed roofing and decking.
The improved technology involves the interaction of 3 ingredients, an air barrier, an air seal, one way Votex vents placed in the high wind vortex area of the roof.